Composites
Particle composites are used to produce radiopacity, lubricity or significantly improve thermal conductivity. At MinVasive Components, we have the expertise to deliver the composites you need, such as radiopaque polyimide tubing as well as boron nitride polyimide with more thermal conductivity than standard polyimide properties.
Radiopaque Polyimide Tubing
At MinVasive Components, our tungsten-loaded polyimide-tubing product is inherently radiopaque for visibility under X-ray and fluoroscopy.
Benefits
- Cost effective alternative to metallic tubing
- Radiopaque image with polymeric properties
|
| |
Units of
Measure |
Test Method |
Radiopaque
Polyimide |
| Tensile
Break Strength |
PSI |
ASTM E8 |
18,100 |
| Elongation
(ultimate) |
% |
ASTM E8 |
37 |
| Modulus of
Elasticity |
KSI |
Calculated
-Young |
491 |
| Dielectric
Strength (DC-dry) |
Volts/.001" |
NEMA MW1000
Section 3.8.3 |
1,000 |
| Moisture
Absorbtion (24 hrs) |
wt% |
ASTM D570 |
0.210 |
| Operating
Temperature |
degrees C |
OTC |
230 |
| Melt
Temperature |
degrees C |
OTC |
Thermoset N/A |
| Softening
Temperature |
degrees C |
OTC |
270 |
| Moldability |
Yes/No |
N/A |
No |
| Coefficient
of Friction (dry) - Dynamic |
N/A |
ASTM 1676 |
0.264 |
| Coefficient
of Friction (dry) - Static |
N/A |
ASTM 1676 |
|
| Scrape
Resistance (no. of 4" cycles to failure @ 300g, .001" thickness) |
inches |
NEMA MW1000
Section 3.59 |
9.25 |
| Biocompatibility / Cytotoxicity (72 hrs) |
Cytotoxic / Not
Cytotoxic |
Geneva Labs
Proc.No. CC1001H |
Most likely Not
Cytotoxic |
| Gamma
Radiation Resistant (8 to 10 megarads for x hrs.) |
Yes/No |
as published by
polymer manufacturer |
Most likely
Yes, not verified |
| Thermal
Conductivity |
W/m*K |
ASTM |
0.223 |
Boron Nitride (Therma-Pull)
Our polyimide includes a special composite material that improves thermal conductivity without sacrificing electrical insulating properties.
Benefits
- 75% more thermally conductive than standard polyimide
| |
Units of
Measure |
Test Method |
Boron
Nitride / PI Results |
| Tensile
Break Strength |
PSI |
ASTM E8 |
17,267 |
| Elongation
(ultimate) |
% |
ASTM E8 |
41.5 |
| Modulus of
Elasticity |
KSI |
Calculated
-Young |
422 |
| Dielectric
Strength (DC-dry) |
Volts/.001" |
NEMA MW1000
Section 3.8.3 |
3,345 |
| Moisture
Absorbtion (24 hrs) |
wt% |
ASTM D570 |
.220 est. |
| Operating
Temperature |
degrees C |
OTC |
230 |
| Melt
Temperature |
degrees C |
OTC |
Thermoset N/A |
| Softening
Temperature |
degrees C |
OTC |
270 |
| Moldability |
Yes/No |
N/A |
No |
| Coefficient
of Friction (dry) - Dynamic |
N/A |
ASTM 1676 |
0.241 |
| Coefficient
of Friction (dry) - Static |
N/A |
ASTM 1676 |
|
| Scrape
Resistance (no. of 4" cycles to failure @ 300g, .001" thickness) |
inches |
NEMA MW1000
Section 3.59 |
9.12 |
| Biocompatibility / Cytotoxicity (72 hrs) |
Cytotoxic / Not
Cytotoxic |
Geneva Labs
Proc.No. CC1001H |
Most likely Not
Cytotoxic |
| Gamma
Radiation Resistant (8 to 10 megarads for x hrs.) |
Yes/No |
as published by
polymer manufacturer |
Most likely
Yes, not verified |
| Thermal
Conductivity |
W/m*K |
ASTM |
0.380 (est.
from DuPont's #'s) |
Contact MinVasive Components Today
We’re available via phone or email. Contact us to discuss your composites needs. |
|