Particle composites are used to produce radiopacity, lubricity or significantly improve thermal conductivity. At MinVasive Components, we have the expertise to deliver the composites you need, such as radiopaque polyimide tubing as well as boron nitride polyimide with more thermal conductivity than standard polyimide properties.

Radiopaque Polyimide Tubing
At MinVasive Components, our tungsten-loaded polyimide-tubing product is inherently radiopaque for visibility under X-ray and fluoroscopy.

Benefits

  • Cost effective alternative to metallic tubing
  • Radiopaque image with polymeric properties

 

  Units of Measure Test Method Radiopaque Polyimide
Tensile Break Strength PSI ASTM E8 18,100
Elongation (ultimate) % ASTM E8 37
Modulus of Elasticity KSI Calculated -Young 491
Dielectric Strength (DC-dry) Volts/.001" NEMA MW1000 Section 3.8.3 1,000
Moisture Absorbtion (24 hrs) wt% ASTM D570 0.210
Operating Temperature degrees C OTC 230
Melt Temperature degrees C OTC Thermoset N/A
Softening Temperature degrees C OTC 270
Moldability Yes/No N/A No
Coefficient of Friction (dry) - Dynamic N/A ASTM 1676 0.264
Coefficient of Friction (dry) - Static N/A ASTM 1676  
Scrape Resistance (no. of 4" cycles to failure @ 300g, .001" thickness) inches NEMA MW1000 Section 3.59 9.25
Biocompatibility / Cytotoxicity (72 hrs) Cytotoxic / Not Cytotoxic Geneva Labs Proc.No. CC1001H Most likely Not Cytotoxic
Gamma Radiation Resistant (8 to 10 megarads for x hrs.) Yes/No as published by polymer manufacturer Most likely Yes, not verified
Thermal Conductivity W/m*K ASTM 0.223

Boron Nitride (Therma-Pull)
Our polyimide includes a special composite material that improves thermal conductivity without sacrificing electrical insulating properties.

Benefits

  • 75% more thermally conductive than standard polyimide
  Units of Measure Test Method Boron Nitride / PI Results
Tensile Break Strength PSI ASTM E8 17,267
Elongation (ultimate) % ASTM E8 41.5
Modulus of Elasticity KSI Calculated -Young 422
Dielectric Strength (DC-dry) Volts/.001" NEMA MW1000 Section 3.8.3 3,345
Moisture Absorbtion (24 hrs) wt% ASTM D570 .220 est.
Operating Temperature degrees C OTC 230
Melt Temperature degrees C OTC Thermoset N/A
Softening Temperature degrees C OTC 270
Moldability Yes/No N/A No
Coefficient of Friction (dry) - Dynamic N/A ASTM 1676 0.241
Coefficient of Friction (dry) - Static N/A ASTM 1676  
Scrape Resistance (no. of 4" cycles to failure @ 300g, .001" thickness) inches NEMA MW1000 Section 3.59 9.12
Biocompatibility / Cytotoxicity (72 hrs) Cytotoxic / Not Cytotoxic Geneva Labs Proc.No. CC1001H Most likely Not Cytotoxic
Gamma Radiation Resistant (8 to 10 megarads for x hrs.) Yes/No as published by polymer manufacturer Most likely Yes, not verified
Thermal Conductivity W/m*K ASTM 0.380 (est. from DuPont's #'s)